Herunterladen Inhalt Inhalt Diese Seite drucken

Wiring Advice; Wiring And Electrical Connection; Secureconnect 100 Terminals; Connection Terminals Of Secureconnect 100F (Leaf-Side Component) - G-U SECUREconnect 100 Montage- Und Bedienungsanleitung

Strom- und datenübertrager
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SECUREconnect 100
5

Wiring advice

5.1 Wiring and electrical connection

Attention:
Observe standards and regulations for extra-low voltage (SELV)
during installation and laying of cables.
The cables must be laid in such a way that they cannot be squeezed in or dammaged in the
area of the lock forend during installation.
Distribution boxes must be accessible for maintenance work. Cable types, lengths, and cross
sections must conform to the specifications.

5.2 SECUREconnect 100 terminals

To facilitate connection, all terminals can be
disconnected from the front.
5.3 Connection terminals of SECUREconnect 100F
(leaf-side component)
5.3.1 Terminals for monitoring contacts (I1 - 14 / V4)
This is where the door monitoring contacts of the electromechanical or motor-driven locks (if
provided) are connected.
With the door closed, the feedback signals are transmitted to SECUREconnect 100R (frame
component) in an encrypted way and put out 1:1 to a potential-free changeover contact via the
relays of a connected I/O module I/O10 (optional).
(see connection diagram in the appendix)
SECUREconnect 100F
38

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Verwandte Produkte für G-U SECUREconnect 100

Inhaltsverzeichnis