Safety advice

It is necessary to ensure that only trained specialists (for the definition thereof see EN 50110-1,
DIN VDE 0105 or IEC 60364) are charged with jobs related to the product (planning, transport,
assembly, installation, start-up, maintenance, repair, dismantling).
Moreover, it is necessary to ensure that the documents required for installation, start-up,
operation, maintenance and repair of the product are made available to the specialists and
observed by them duly.
Danger !
Installation works involving the use of electrical equipment are
dangerous.
Insufficient wire cross sections may cause a fire. Therefore it is
important to always observe the specified cross sections.
Connections to a 230V mains are dangerous to life !
The installation of electrical components must be carried out by trained
electricians only. Non-observance of the installation advice may result in fire
and other hazards.
• Observe operating instructions before connection to the mains.
• Relieve supply line from strain by an appropriate means.
• Do not damage connecting cables.
• Use enclosed rubber grommet on cable outlet from profile.
• Observe standards and regulations for extra-low voltage (SELV) during installation and
laying of cables.
• By no means switch a 'permanent OPEN' contact when using the unit on smoke and fire
protection doors (DIN 18250) ! This will nullify the door assembly's fire approval.
• The door leaf component of SECUREconnect has an integral energy storage ensuring
that in the event of a power failure during short-time 'OPEN', the retracted latchbolts of all
mechatronic G.U-BKS locks will eject to be ready for locking. This provides for safe and
reliable door locking in the event of a fire.
• SECUREconnect 100R features an internal 2 A fuse which is not accessible from outside
and not suitable for being exchanged. Opening the device will damage it and nullify its
warranty.
• Disconnecting the unit from the mains is done by pulling the power plug from the
socket.
The socket must be freely accessible.
If SECUREconnect 100 is connected to the electricity supply permanently, it is necessary
to provide for switch off by means of a suitable and appropriately marked device on the
building's distribution board, e.g. a switch, fuse, or automatic cutout.
This manual is part of the product and must remain with the end user.