Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Description; Field Of Application - G-U SECUREconnect 100 Montage- Und Bedienungsanleitung

Strom- und datenübertrager
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SECUREconnect 100
2

Technical description

2.1 Field of application

The SECUREconnect 100R and -F components are designed for vertical installation in the the
frame and the door leaf, respectively.
It is not permitted to operate the unit in exterior gate or door assemblies where ambient condi-
tions require a higher protection class than IP 40.
SECUREconnect 100 must not be used for purposes other than the intended use (see
chapter 1 Information).
'Intended use' comprises the observance of the manufacturer's operating and service instruc-
tions which is essential for the avoidance of damage and injury.
The companies G-U and BKS exclude any liability for damage arising from changes made on
the lock or on the lock connection without their consent.
• Suitable for installation in timber, PVC, and metal door assemblies with the use of profile-
specific screw-on type face plates.
• Short-circuit proof power transmission between door frame and leaf.
• Encrypted data transmission.
All deliveries are made on the basis of the General Terms and Conditions of the company GU.
SECUREconnect 100R for installation in the door frame
• Power and data transmission unit for motor-driven or electromechanical locking systems
from GU and BKS.
• Communication interface to the GU-BKS-NET bus, output of lock statuses to IO10 (relay
box).
• Status indicator LEDs.
• Optional voltage supply of 24 V DC or 230V
SECUREconnect 100F for installation in the door leaf
• Power and data transmission unit for motor-driven or electromechanical locking systems
from GU and BKS.
• Long-life tappet contacts (no need of a cable duct).
• Any door opening angle possible
• Unhindered hinging and unhinging of door leaf.
• 4 inputs for transmission of lock statuses
• Power output 20 mA for connection of LED signalling 'open'.
• Status indicator LEDs.
• Compartment for extension modules for possible future applications.
• Once installed, the unit is maintenance-free.
Operating parameters
Supply voltage
IP Protection class
Protection system
Ambient temperature
32
230V AC 50/60 Hz 0.25 A or 24V DC stabilised 1.0 A
IP 40
II
-20 °C ... +45 °C