Start-up

Please observe the mounting advice given in chapter 4!
1. Install SECUREconnect 100F in the door leaf and connect the electrical lock according to
the particular connection diagram.
ATTENTION!
Cables may be damaged when turning in the fastening screws.
We recommend: Insert screw through device and fix cable beside the screw with adhesive
tape.
2. Install SECUREconnect 100R in the door frame exactly on the opposite side.
Ensure that the tappet contacts of SECUREconnect 100F exactly coincide with the contact sur-
faces of SECUREconnect 100R as the door closes (see also installation drawing 0-45733-L0).
3. Connect SECUREconnect 100R to the operating voltage supply (230V AC or 24V DC).

6.1 Establishing communication

6.1.1 Coding
At start-up, the two status LEDs of SECUREconnect 100 will be flashing alternately red and
green as soon as the operating voltage has been applied.
The status LED on SECUREconnect 100F flashes green as soon as the door has been closed
once for a short time and supplied with voltage. This indicates normal functioning.
At this stage, the two SECURE connect 100 components are not yet coupled, so a SECURE-
connect 100R component could communicate openly and function perfectly with any SECURE-
connect 100F component.
The first level of security consists in the fact that the exchange data between the two compo-
nents are AES-encrypted.
As a second level of security, SECUREconnect 100R and SECUREconnect 100F – after hav-
ing been connected with each other for 15 minutes – enter into an inseparable "partnership" by
generating a random code which will be exchanged between the two components later on.
Afterwards SECUREconnect 100R and SECUREconnect 100F will no longer accept any other
frame or leaf components.
6.1.2 Separation
The code uniting SECUREconnect 100R and SECUREconnect 100F cannot be changed, this
means exchanging just one component is not possible.
In the event of failure, SECUREconnect 100R and SECUREconnect 100F must always
exchanged as a pair.