Power and Data Transmission Unit
5.4 Connection terminals of SECUREconnect 100R
(frame-side component)
5.4.1 Terminals for external 24V DC voltage supply
The terminals V42 and G42 are provided for the connection of an external 24V DC voltage
supply to operate SECUREconnect 100
Attention:
Only 24 V DC voltage sources in accordance with EN 60950 may be used.
Stabilized
power supply
230 / 24 V, 1 A
5.4.2 Connection terminals for GU-BKS-NET bus
Terminals LA and LB are assigned for the connection of the GU-BKS-NET bus.
This bus allows SECUREconnect 100 to communicate with other compatible bus participants
(e.g. escape door control unit FTNT10).
Further functional details are to be taken from the GU-BKS-NET installation and operating
instructions.
5.4.3 Connection terminals for control inputs
The terminals V4, 91, 92, 93 are provided for potential-free contacts required to open and close
the door. (Pushbutton, relays, access control etc.)
*) Connecting at output „Ausgang"
SECUREconnect 100R
*)
41