• after the assembly, the fireplace insert and the installation must be filled up with the
water through the open expansion vessel.
Fig. 25. Connection of the fireplace insert in the opened system - page 173.
Necessary conditions for connecting the fireplace in the closed system:
• in addition to the coil receiving too high temperature, a diaphragm expansion vessel
should be installed;
• the coil must be connected to the water supply with cold water through a
thermostatic valve with temperature probe installed in the fireplace body;
• (connection of the valve is made directly to the coil and to the installation of cold
water without intermediate components);
• the insert should be secured with a safety valve of 0.2 MPa (2 bar);
• water refilling in the fireplace installation and warm heating should be made outside
the fireplace, on the return water pipe (above 1 m).
Fig. 26. Connection the fireplace insert in the closed system. – page 174
3.4. AUTOMATIC CONTROL - CENTRAL
Hitze is not responsible for damage caused by improper connections made by
people with insufficient qualifications or improper use of the device.
The water jacket assembly must be directed by the central with the thermostat
(temperature) sensor, which will enable the startup of the circulation pump, the sounder
indicating that the water temperature in the system has been exceeded. For the fireplaces
of the ALBERO AQUASYSTEM series by Hitze, the control automatics in the form of
a heating circuit controller with a fireplace can be used.
Basic functions that a regulator should have:
the controller controls the central heating circulating pump and the pump charging
tank with hot water;
• the pump is running from the time the water temperature exceeds the set value (the
controller has a clock controlling warm water priority at selected times of the day);
• the controller prevents the installation from freezing, automatically switches on the
circulation pump when the measured temperature is less than 4°C;
More information on the setting options, service and warranty conditions can be found
on the appropriate manufacturer's website.
WARNING:
The controller should be installed away from heat sources.
Do not mount it on the housing.
The connection wires should not touch the metal construction.

4. TRANSPORT, ASSEMBLY, INSTALLATION OF THE INSERT

4.1. TRANSPORT AND HANDLING

• the insert is delivered as an assembled unit, fastened to a palette and wrapped in
stretch foil;
• the fireplace should be transported in a vertical position;
• after unpacking, check the insert for any transport related damage;
• unpack the insert in the vicinity of the installation site; exercise caution when moving
the insert (preferably on a cart) (paying special attention to the door and glass);
• the packaging materials of the fireplace insert are not toxic or harmful and should be
recycled or stored by the User;