Herunterladen Inhalt Inhalt Diese Seite drucken

Initial Operation; Operating Modes; Power Switch - clage SX 50 Gebrauchs- Und Montageanleitung

Vorschau ausblenden Andere Handbücher für SX 50:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SX 50 / SX 80 / SX 100 / SX 120

5. Initial operation

Operating modes

Single Power Operation
Connection without off-peak contact.
The appliance heats with the adjusted performance. The 'FAST' button is only used for the reset and diagnose func-
tions.
Connection with off-peak contact.
If the 'FAST' button (fig. 1, ref. B) is activated, the device heats once to the configured temperature. All LED ther-
mal capacity indicators (fig. 1, ref. 4,5 and 6) light up as soon as the configured temperature has been reached.
Afterwards, the device turns itself off automatically.
Double Power Operation
Connection without off-peak contact.
The reservoir heats with the configured basic performance. The "FAST function" activates a heating cycle at higher
installed power in order to accelerate the heating-up procedure. To start this function, press the 'FAST' button. The LED
'FAST' (fig. 1, ref. 3) lights up. The function turns itself off automatically, as the soon as the configured temperature has
been reached. The LED 'FAST' turns off.
Connection with off-peak contact.
During off-peak time the device heats with the configured basic performance.
The "FAST function" activates a heating cycle at higher power in order to accelerate the heating-up procedure. To start
this function, press the 'FAST' button. The LED 'FAST' lights up. The function turns itself off again automatically as soon
as the configured temperature has been reached. The LED 'FAST' turns off. The rest of the time, the device does not
heat. If the 'FAST' button is activated, the device heats once to the configured temperature. All 3 LED thermal capacity
indicators light up as soon as the configured temperature has been reached. Afterwards, the device turns itself off
automatically.
Boiler Mode
Connection without off-peak contact.
The device does not heat by default. If the 'FAST' button is activated, the device heats once to the configured temper-
ature. All 3 LED thermal capacity indicators (fig. 1, ref. 4,5 and 6) light up as soon as the configured temperature has
been reached. Afterwards, the device turns itself off automatically. Each further heating process must be started by
pushing the button 'FAST'.

Power switch

Set the power switch "S1" to the correct operating mode on the electronic board. Set the desired load according to the
connection examples.
The power switch is manufacturer set in position 5 for 50 (E), 80 (E) and 100 (E) models and in position 6 for 120 (E).
Power Switch "S1"
www.clage-com.ru
Double power switch positions 5 / 6 / 7
Single power switch positions 1/ 2 / 3 / 4
Boiler mode switch positions 8 / 9 / 0
22
Mode of Operation
(see page IV)
(see page V)
(see page V)

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sx 80Sx 100Sx 120

Inhaltsverzeichnis