"Fault no.: 20"
Possible cause:
R
Battery charging cable defective
R
Connection for battery charging cable defective
R
Battery voltage of lead-acid batteries below 6 V
R
Battery voltage of lithium iron phosphate batteries
below 9 V
R
Voltage measurement faulty
Remedy:
1. Check battery charging cable for continuity.
2. Replace defective battery charging cable.
3. Check connection for battery charging cable.
4. Replace defective connection for battery charging
cable.
5. Check rated battery voltage.
6. Charge only lead-acid batteries and lithium iron
phosphate batteries with a rated voltage of 12 V or
24 V.
7. Replace power module.
"Fault no.: 30"
Possible cause:
Battery greater than 24 V rated voltage connected.
Remedy:
1. Check rated battery voltage.
2. Charge only lead-acid batteries and lithium iron
phosphate batteries with a rated voltage of 12 V or
24 V.
"Fault no.: 40"
Possible cause:
No valid parameter set loaded.
Remedy:
1. Reload firmware.
DANGER - Risk of electric shock from live
parts. Observe the electrical engineering safety
regulations.
2. Connect M1 circuit board from Bosch Customer
Service and check BAT 645 for proper operation.
3. Replace M1 circuit board if BAT 645 functions with
M1 circuit board from Bosch Customer Service.
5.3

Power module faults

"Fault no.: 100" (readiness fault)
Possible cause:
Power module has shut down.
Remedy:
Replace power module.
Robert Bosch GmbH
Faults & Troubleshooting | BAT 645 | 23
"Fault no.: 110" (bus)
Possible cause:
Power module is not connected to M1 circuit board.
Remedy:
Check connection between M1 circuit board and
power module (see sec. 6) and reestablish.
"Fault no.: 120" (fan)
Possible cause:
Fan on power module is defective.
Remedy:
DANGER - Risk of electric shock from live
parts. Observe the electrical engineering safety
regulations.
1. Check connection between fan and power module
(see sec. 6) and reestablish.
2. Clean fan.
3. Run self-test.
i
The fan must function in a self-test.
4. Replace fan if fan does not function in a self-test.
5. Replace power module if new fan does not function.
"Fault no.: 130" (temperature monitoring)
Possible cause:
Temperature sensor on power module is defective.
Remedy:
Replace power module.
"Fault no.: 140" (mains power supply)
Possible cause:
No mains power supply to power module
Remedy:
1. Check the power supply cable for continuity and
replace if necessary.
DANGER - Risk of electric shock from live
parts. Observe the electrical engineering safety
regulations.
2. Check voltage at measuring points X4 and X2
directly behind the power inlet socket connector on
the power supply module (see sec. 5.6).
 Voltage must be 230 V.
 If the voltage differs or is not present, the pow-
er inlet socket connector or the connecting ca-
bles from the power inlet socket connector to the
power module are defective.
3. Check the power inlet socket connector and
connecting cables from the power inlet socket
connector to the power module and replace if
necessary.