Herunterladen Inhalt Inhalt Diese Seite drucken

Faults; Aintenance; Maintenance; Spare And Wearing Parts - Bosch BML 2415 Betriebsanleitung

Batterie ladegerät für 12 v / 24 v batterien
Vorschau ausblenden Andere Handbücher für BML 2415:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
9. Monitor the charge current constantly on the display
instrument (Fig. 1, Pos. 1). The yellow LED (Fig. 1,
Pos. 4) will be lit during charging.
i
When the green LED (Fig. 1, Pos. 3) lights up, a
voltage of 2.3 V or 2.4 V (depending on the battery
temperature set) has been reached in each cell.
In a properly working battery, this means that the
battery is about 60% charged and can be used.
!
The battery must be tested before trickle char-
ging. Only batteries in perfect working order may
be charged further or trickle charged. To continue
charging, to trickle charge or to run the battery in
buffer mode, the battery temperature switch must
be switched to "Warm battery".
10. When charging is complete, switch off the charger.
11. Remove the terminal clips from the battery.
4.�

Faults

Charger does not respond after switching on and the
red LED does not light:
Check power supply.
Red LED flashes when the terminal clips have been
attached to the battery:
Check polarity. The red clip must be attached to
the positive terminal (+) and the black clip must be
attached to the negative terminal (-).
Robert Bosch GmbH
Operation | B�L 241� | 1�
5.

Maintenance

�.1
�aintenance
The charger housing and display must only be wiped with
soft cloths and neutral cleaning agents. Do not use abrasi-
ve cleaning agents or coarse workshop cleaning rags.
�.2

Spare and wearing parts

Description
Charging cables with PVC insulation
Wearing part
<)
6.

Technical data

Property
Charge current at 12 V
(arithm. / eff.)
Charge current at 24 V
(arithm. / eff.)
Length of charging cable
*)
Cross section of charging cable
Power consumption
Weight
Charging characteristic
Final charge voltage for
setting > 15 °C
Final charge voltage for
setting < 15 °C
Functional temperature range
Mains voltage/mains frequency
Fuse
Battery nominal voltage
Protection type (DIN 40050)
Protection class (DIN 40530)
Dimensions (WxHxD)
Noise emission value (Lpa)
associated with work
Emitted interference level
The charging cables must not be changed
*)
B�L 241� | 1�
| 1�
en
Order Number
1 684 460 235
<)
Value, Range
max. 15 A / max. 22.5 A
max. 10 A / max. 15 A
2 m
4.0 mm
2
280 W
approx. 7.3 kg
WU
2.3 V per cell
2.4 V per cell
0 °C – 40 °C
230 V / 50 Hz
H 250 T 3.15 A
12 V / 24 V
IP 20
II
260 x 165 x 283 mm
70 dB(A)
DIN 40839 Emitted in-
terference level I
|
1 689 979 993
2009-05-07

Quicklinks ausblenden: