Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; Faults; Replacement And Wearing Parts; Cleaning - Bosch BAT 490 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
6.

Maintenance

6.1

Faults

Problem
No BAT 490 function
after switch-on
(red LED does not light)
Red LED flashes after connec-
ting the battery
6.2

Replacement and wearing parts

Designation
2 m power cord
<)
Red/black charging cable set
(3 m; 10 mm
)
2
<)
Red/black charging cable set
(5 m; 16 mm
)
2
<)
Wearing part
<)
6.�

Cleaning

Only use a soft cloth and neutral detergents to clean
the housing and display of the BAT 490. Do not use ab-
rasive cleaning agents and coarse workshop cloths.
6.4

Disposal

�his BA� 4�� is subject to European guideli-
nes 2��2/�6/EG (WEEE).
Old electrical and electronic devices, inclu-
dingcables and accessories or batteries must
be disposed of separate to household waste.
Please use the return and collection sys-
tems in place for disposal in your area.
Damage to the environment and hazards
to personal health are prevented by pro-
perly disposing of BAT 490.
Robert Bosch GmbH
Action to be taken
Pull the mains connector and
check the power supply and po-
wer cord.
Check the polarity at the batte-
ry. The red charging clip must
be connected to the positive
post (+) and the black charging
clip to the negative post (–) of
the battery.
Overload: Maximum current va-
lues reached for Buffer and
Backup mode.
The red LED stops flashing on-
ce the overload situation has
been rectified.
Order number
1 684 461 168
1 687 011 519
1 687 011 520
Maintenance | BA� 4�� | 25
7.
Technical data
Property
Charging current max.
Length of charging cable
*)
Length of charging cable (USA)
Charging cable cross-section
Power input
Weight
Standard charging characteristic
Expert-charger characteristic
Standard charging cut-off voltage
(temperature-regulated)
12 Volt
24 Volt
Backup mode 12 V
Backup mode 24 V
Buffer mode 12 V
Buffer mode 24 V
Funktions-Temperaturbereich
Mains voltage/frequency (230 V)
Mains voltage/frequency (100 V)
Rated battery voltage
Degree of protection (DIN 40050)
Safety class (DIN 40530)
Dimensions (W x H x D)
Dimensions (W x H x D) (USA)
Workplace-related
noise emission value (Lpa)
Conducted interference level
The charging cables are not to be modified.
*)
BA� 4�� | 25
| 25
en
Value, Range
90 A
3 m
9.8 ft
*)
10 mm
2
1600 W
10,5 kg
IUIaIaI
IUoU
14 V – 14,4 V
28 V – 28,8 V
10 V – 13 V / 3 A – 10 A
20 V – 26 V / 3 A – 10 A
11 V – 14 V / 3 A – 90 A
22 V – 28 V / 3 A – 45 A
0 °C – 40 °C
230 V, 50/60 Hz
100 V – 120 V, 50/60 Hz
12 V / 24 V
IP 20
I
300 x 200 x 390 mm
11.8 x 7.9 x 15.4 inch
< 70 dB(A)
DIN 40839 Conducted
interference level I
|
1 689 989 068
2012-10-30

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis