TROUBLESHOOTING

Problem
No power after turning on the
power switch
Controller display E1
Not heating up after you have
finished setting the steps
Water not being pumped from
the tap
Wort not pumped out
Possible causes
Controller cord is not
connected to the PCB
Dry burn before adding water
and the thermostat overload
has cut off
Temperature sensor cord is not
connected to the PCB
The start button wasn't held
down for long enough
Wire connected incorrectly
Tap not open
Pump and tap not connected
Air or bubbles in the pump
Air or bubbles in the pump
Filter tube or filter basket is
blocked
Wort is too thick and sticky
What to do
Reconnect controller cord
to PCB
Wait for the brewer to cool
down to below 175°C
Reconnect sensor cord to PCB
Hold down the start button for
3 seconds
Reconnect wire correctly
Open the tap
Connect the pump to tap with
quick connector
Make sure the water level is
higher than the tap inlet, turn
off the pump ,open one of the
valves and then open the tap
to get the air out of the pump
Make sure the water level is
higher than the tap inlet, turn
off the pump, open one of the
valves and then open the tap
to get the air out of the pump
Power off the brewer, take all
the wort out when it is cool
enough and clean the filter
tube or filter basket
Fill with water