Troubleshooting table

Malfunctions can occur in all electrical appliances. This does not necessarily mean
there is a defect in the appliance. For this reason, please check the tables to see if you
can correct the malfunction.
WARNING
Risk of electric shock in case of improper repair!
Never try to repair a defective or suspected defective appliance yourself. You can put
your own and future users' lives in danger. Only authorised specialists are allowed to
carry out this repair work.
Problem
Possible cause
Compressor OFF,
No electricity to socket.
control element
Mains plug is loose.
OFF.
Compressor off,
Desired temperature has
control unit on.
been reached.
Appliance cools
Temperature has been set
too quickly.
too low.
T h e
a p p l i a n c e
Temperature has been set
doesn't cool suffi-
too high.
ciently.
Door not tightly closed or
door seal is not completely
tight.
The appliance is near a heat
source or sunlight.
Minimum distances not main-
tained (too short).
Too many bottles of wine
stored.
Ambient temperature too low
or too high.
Compressor seems defec-
tive.
Troubleshooting table
Solutions, tips, explanations
Check the socket with another appliance.
Check the tightness of the mains plug.
Further cooling not required. When the in-
side temperature rises, the compressor au-
tomatically switches on.
Select a higher setting (see „Setting the tem-
perature" on page EN-11).
Select a lower setting (see „Setting the tem-
perature" on page EN-11).
See 'Checking and cleaning the door seals'
on page EN-15.
Place insulation plate between the applianc-
es or change location.
Adhere to the minimum wall distances (see
„Choosing a suitable location" on page
EN-17).
Do not exceed the maximum nominal ca-
pacity (see data sheet at the end of this user
manual).
Adjust the ambient temperature according to
the climate class (see data sheet at the end
of this user manual).
Set the temperature to 5°C (41°F). If the
compressor does not switch on within an
hour, please contact our Service department
(see page EN-23).
Page EN-21