Technical information

Electrical connection

GB
!
Arrange the electrical power supply within the
decorative flue dimensions.
!
When making the electrical connections, check that
the voltage values correspond to those indicated on
the data plate inside the appliance itself.
!
In case your appliance is not furnished with a non
separating flexible cable and has no plug, or has not
got any other device ensuring omnipolar
disconnection from the electricity main, with a
contact opening distance of at least 3 mm, such
separating device ensuring disconnection from the
main must be included in the fixed installation.
!
If your unit features a power lead and plug, position
this so the plug is accessible.

Technical data

Model
Dimensions
Gross weight
Absorption
Flow rate
Grease filters
Suction
surface area
Model
Dimensions
Gross weight
Absorption
Flow rate
Grease filters
Suction
surface area
12
HIP6 IX / HIP6 F IX
width 59.8 cm
height 68/119 cm
depth 49 cm
Outlet pipe diameter 15 cm
16.8 Kg
Total 215 W
Motor 1x135 W
Lamps 2x40 W
430 m
/h
3
1487 cm
2
HIP6 P IX
width 59.8 cm
height 68/119 cm
depth 49 cm
Outlet pipe diameter 15 cm
17.8 Kg
Total 270 W
Motor 1x190 W
Lamps 2x40 W
585 m
/h
3
1487 cm
2
HIP9 IX / HIP9 F IX
width 89.8 cm
height 68/119 cm
depth 49 cm
Outlet pipe diameter 15 cm
17.9 Kg
Total 215 W
Motor 1x135 W
Lamps 2x40 W
430 m
/h
3
2287 cm
2
HIP9 P IX
width 89.8 cm
height 68/119 cm
depth 49 cm
Outlet pipe diameter 15 cm
18.9 Kg
Total 270 W
Motor 1x190 W
Lamps 2x40 W
585 m
/h
3
2287 cm
2