Herunterladen Inhalt Inhalt Diese Seite drucken

Items Supplied; How To Use; Notes On Operation; Automatic Defrosting - Silvercrest SLE 450 A1 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SLE 450 A1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

__CPE111670_B1.book Seite 53 Donnerstag, 12. März 2015 11:48 11

4. Items supplied

1 Dehumidifier with water tank 5
1 Hose 24
1 Garden hose adapter 25
1 Set of operating instructions

5. How to use

• Remove all packing material.
• Remove all transport packing material.
• Strip off the foil from the operating pan-
el.
• Check to ensure that all parts are pres-
ent and undamaged.
1. Place the device on a level, dry and solid
surface.
2. Let the device rest in its working position
for about 30 minutes, so that the coolant
fluid can settle.
3. Check that the float in the water tank 26
can move freely. To do this, pull out the
empty water tank 5 and turn it upside
down so that the float moves.
4. Check that the water tank 5 is inserted
correctly. If it is installed incorrectly, or if
the water tank has been removed, the
LED|13 WASSERTANK VOLL (TANK
FULL) will illuminate.
5. Connect the mains plug 11 to a ground-
ed power socket.

6. Notes on operation

• If the relative humidity in residential
rooms is continuously excessive, the
cause should be found and rectified.
(Continuous ventilation - i.e. for several
years - is generally not reasonable.)
• The optimum ambient temperature for
removing humidity from the air is 5|°C
to 35|°C. Below 5|°C, the use of a de-
humidifier is not helpful, as there is only
relatively little humidity in the air.
• During operation, the room temperature
may rise by between 1|°C and 4|°C,
depending on room size. This is normal.

Automatic defrosting

In order to prevent the device from freezing
over while in continuous operation, it de-
frosts itself automatically. To do this, the de-
humidification process is interrupted, and
the motor switches to its highest setting.
The intervals at which this happens vary.
Conditions
Temperature:
no defrosting
over 20|°C
after 40 minutes dehu-
Temperature:
midification,
12|°C to 20|°C
8 minutes defrosting
after 25 minutes dehu-
Temperature:
midification,
5|°C to 12|°C
10 minutes defrosting
Temperature:
operation not possible
under 5|°C

7. Operation

7.1 Switching on and off

• By pressing the button STAND-BY 18,
you can switch the device on and off.
The corresponding LEDs illuminate or go
out.
- The device will start with the setting
last selected.
• If a timer has been set, the device will
shut down after the time has run out (1-
24 hours).
• If a value has been set for relative hu-
midity in the ZIEL-LUFTFEUCHTIGKEIT
(TARGET HUMIDITY) mode, the device
will stop when the value has been
reached, and re-start when the value is
exceeded again.
Defrosting
53
GB

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis