Herunterladen Inhalt Inhalt Diese Seite drucken

Safety/Warning; Overheating; Maintenance / Cleaning - Vortice 500 Betriebsanleitung

Electric heater
Vorschau ausblenden Andere Handbücher für 500:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
ENGLISH
Safety /warning
Warning:
!
this symbol indicates that care must
be taken to avoid injury to the user
• Do not use this appliance for functions other than
those described in this booklet
• After removing the appliance from its packaging,
ensure that it is complete and undamaged. If in
doubt contact a professionally qualified electrician or
Vortice.
• If you decide to stop using the appliance, switch it off
and disconnect it from the power supply, storing it
out of reach of children and infirm persons.
• Do not sit on the appliance or leave objects standing
on it.
• Do not use the appliance where flammable vapours
are present (spirit, insecticides, petrol, explosives,
etc.
• Any flammable objects must be positioned at a
distance of minimum 200 mm from the air inlet and
600 mm from the hot air outlet.
• Do not make modifications of any kind to this
appliance.
• The maintenance instructions must be followed to
avoid damage and/or excessive wear and tear to the
appliance.
• The electric heater is designed for connection with a
duct of the same nominal diameter. The duct must
be completely inserted on the heater until it reaches
the stop. By ensuring this, the rubber seal placed on
the heater will be well fitted inside the connection
duct and the correct connection is completed.
Caution:
!
this symbol indicates that care must
be taken to avoid damaging the appliance
• Do not expose this appliance to the weather (rain,
sun, etc.).
• Regularly inspect the appliance for visible defects. If
the appliance does not function correctly, do not use
it and contact Vortice immediately.
• If the appliance does not function correctly or
develops a fault, contact Vortice immediately. Ensure
that only genuine original Vortice spares are used for
any repairs.
• Should the appliance be dropped or suffer a heavy
blow, have it checked by Vortice immediately.
• The appliance must be installed in such a way that its
electrical connections box is easily accessible.
• Switch off the appliance at the main switch: a) if the
appliance does not function correctly; b) before
cleaning the outside of the appliance, c) if the
appliance is not to be used for any length of time.
• This appliance must be connected to an efficient
earthing system in compliance with applicable safety
standards.
• Check that the electrical power supply/socket
provides the maximum electrical power required by
the appliance. Otherwise contact a professionally
10
qualified person immediately.
• It is recommended to insert a warning that forbids to
cover the duct on the supply side of the ventilation
system.
• The electrical wiring diagram is shown inside the
wiring box cover.
• The electric heater is designed for connection with a
duct of the same nominal diameter. The duct must be
completely inserted on the heater until it reaches its
stop. Thanks to this, the rubber seal placed on the
heater will be well inside the duct connection and the
correct connection is ensured.
• The heater must be installed so that the connecting
ducts are at least two times longer than its diameter
on both sides. (Except in the event that the heater is
installed at the beginning or end of the duct)
• The heater must be installed so that it can be
checked, maintained or replaced easily.
• If it is not possible to fix the heater to the support
structure, use a metal sleeve without a rubber profile.
• The heater must not be insulated from any insulating
material.
• If the heater is installed at the end of the duct, the
hole must be protected with a grid or other safety
device capable of preventing contact with the
armored resistances.
N.B.
• To prevent damage and other risks caused by
overheating, the appliance is fitted with a
(manual reset) safety thermostat that stops the
appliance.
If the safety thermostat trips, switch off power,
check the appliance and reset the thermostat by
pressing the button market RESET inside the
connections box.
If the thermostat trips repeatedly, have the
appliance checked by Vortice.
• The heaters have an auxiliary contact that allows
remote control of the resistance by means of an
external switch or a room thermostat.
• ELECTRIC HEATER 2400 must be mounted on the
fresh air supply ducts in the home.
ELECTRIC HEATER 2400 can be activated from
the control panel of the heat recovery unit to
which the heater is associated the default value
that can be modified is setted to: NO

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

75012002400

Inhaltsverzeichnis