Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch PLS Benutzerhandbuch Seite 21

Parking lot sensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Parking Lot Sensor | PLS
Figure 10 Adhesive application
Please note that, as soon as the two components are mixed, the adhesive cures within a few minutes.
INFORMATION:
Once the adhesive in the mixing tube has cured, it cannot be used again. At room temperature, a
typical processing time for the adhesive is about 5 minutes.
Now you can mount the sensor in the center of the parking space by applying light pressure on the sensor base (see
Fig. 12 Sensor base attachment). Make sure that the sensor is centered in the parking space and that the Bosch logo
on the sensor base points towards the access road (see Figure 13 Sensor base installed). Subsequent twisting of the
sensor base is not possible.
Figure 11 Adhesive amount
7 | 14