Problem and alarm code
The appliance does not fill
with water.
The display shows
.
The appliance does not
drain the water.
The display shows
The anti-flood device is on.
The display shows
The appliance stops and
starts more times during op-
eration.
The program lasts too long.
The remaining time in the
display increases and skips
nearly to the end of pro-
gram time.
Small leak from the appli-
ance door.
The appliance door is diffi-
cult to close.
Rattling/knocking sounds
from inside the appliance.
The appliance trips the cir-
cuit-beaker.
• Make sure that the water tap is open.
• Make sure that the pressure of the water supply is not
too low. For this information, contact your local water
or
authority.
• Make sure that the water tap is not clogged.
• Make sure that the filter in the inlet hose is not clogged.
• Make sure that the inlet hose has no kinks or bends.
• Make sure that the sink spigot is not clogged.
• Make sure that the filter in the outlet hose is not clogged.
• Make sure that the interior filter system is not clogged.
.
• Make sure that the drain hose has no kinks or bends.
• Close the water tap and contact an Authorised Service
Centre.
.
• It is normal. It provides optimal cleaning results and en-
ergy savings.
• If the delayed start option is set, cancel the delay setting
or wait for the end of the countdown.
• This is not a defect. The appliance is working correctly.
• The appliance is not levelled. Loosen or tighten the ad-
justable feet (if applicable).
• The appliance door is not centred on the tub. Adjust the
rear foot (if applicable).
• The appliance is not levelled. Loosen or tighten the ad-
justable feet (if applicable).
• Parts of the tableware are protruding from the baskets.
• The tableware is not properly arranged in the baskets.
Refer to basket loading leaflet.
• Make sure that the spray arms can rotate freely.
• The amperage is insufficient to supply simultaneously all
the appliances in use. Check the socket amperage and
the capacity of the meter or turn off one of the applian-
ces in use.
• Internal electrical fault of the appliance. Contact an Au-
thorised Service Centre.
Possible cause and solution