Input Voltage range 1 AC 200 V - 240 V, ± 10% (unfiltered)
Order No.
6SE6420-
[A]
IEC Fuse
6
3NA
UL/IEC Fuse
[A]
Semiconductor
3NE
(Siemens)
3
UL Fuse
Non-
[A]
Semiconductor
1
[A]
UL/IEC Type E
Motor Controller
3RV
NKJH (Siemens)
2
[mm
]
2
Input Cable min.
[awg]
[mm
]
2
Input Cable max.
[awg]
[mm
]
Output Cable
2
min.
[awg]
[mm
]
Output Cable
2
max.
[awg]
Input Voltage range 3 AC 200 V - 240 V, ± 10% (with built in Class A filter)
Order No.
6SE6420-
[A]
IEC Fuse
6
3NA
UL/IEC Fuse
[A]
Semiconductor
3NE
(Siemens)
3
UL Fuse
Non-
[A]
Semiconductor
1
UL/IEC Type E
[A]
Motor Controller
3RV
NKJH (Siemens)
2
[mm
]
2
Input Cable min.
[awg]
[mm
]
2
Input Cable max.
[awg]
[mm
]
Output Cable
2
min.
[awg]
[mm
]
Output Cable
2
max.
[awg]
12
2UC11-
2UC12-
2UC13-
2AA1
5AA1
7AA1
16
16
16
3805
3805
3805
16
16
16
1813-0
1813-0
1813-0
15
15
15
16
16
16
2011-4AA##
2021-4AA##
1031-4AA$$
1.0
1.0
1.0
18
18
18
2.5
2.5
2.5
14
14
14
1.0
1.0
1.0
18
18
18
2.5
2.5
2.5
14
14
14
2AC23-
2AC24-
2AC25-
0CA1
0CA1
5CA1
25
32
35
3810
3812
3814
35
35
35
1803-0
1803-0
1803-0
35
35
35
40
40
40
1031-4FA$$
2.5
2.5
4.0
14
14
12
10.0
10.0
10.0
8
8
8
1.5
2.5
4.0
16
14
12
10.0
10.0
10.0
8
8
8
MICROMASTER 420/430/440 — Getting Started — 01/18 — A5E02779537A-AF
2UC15-
2UC17-
2UC21-
5AA1
5AA1
1BA1
16
16
20
3805
3805
3807
16
16
20
1813-0
1813-0
1814-0
15
15
20
16
16
28
1.0
1.0
2.5
18
18
14
2.5
2.5
6
14
14
10
1.0
1.0
1.0
18
18
18
2.5
2.5
6.0
14
14
10
2UC21-
2UC22-
5BA1
2BA1
20
35
3807
3814
20
35
1814-0
1803-0
20
35
28
40
-
-
2021-4NA##
-
1031-
-
4FA$$
2.5
4.0
14
12
6
6
10
10
1.0
1.0
18
18
6.0
6.0
10
10
2UC23-
0CA1
50
3820
50
1817-0
50
40
-
-
1031-
4FA$$
6.0
10
10
8
1.5
16
10.0
8