6.5 Technical data: Flexlite GX 300A/400A/420A (water-cooled)

Flexlite GX
Feature
Welding process
Contact tip
Method of guidance
Type of cooling
Coolant flow rate (l/min)
Coolant max. pressure (bar)
Min. cooling power at 1.6l/min * (kW) IEC 60974-7
Min. flow rate (l/min)
Type of connection
Wire diameters (mm)
Load capacity:
35% / Ar + 18% CO₂
60% / Ar + 18% CO₂
100% / Ar + 18% CO₂
35% / CO₂
60% / CO₂
100% / CO₂
Gas flow (l/min) in load capacity test
Filler wire diameter in load capacity
test
Stick out length in load capacity test
Filler wire diameters (mm):
Fe
Fe-MC/FC
Ss
Ss-MC/FC
Al
Operating temperature range
Storage temperature range
Pistol grip handle
Rotating neck
Changeable neck
© Kemppi
403W /
405WS
405W
MIG/MAG
MIG/MAG
M10x1
M10x1
Manual
Manual
Liquid
Liquid
1
1
5
5
0.9
0.9
1
1
Euro
Euro
0.8...1.6
1.0...1.6
-
-
-
-
400 A
300 A
-
-
-
-
-
-
20
20
1.6
1.6
22
22
0.8...1.6
-
0.9...1.6
-
0.8...1.6
1.0...1.2
0.9...1.6
-
0.8...1.6
1.2...1.6
-
-
20°C...+40°C
20°C...+40°C
-
-
40°C...+60°C
40°C...+60°C
Yes
Yes
No
No
No
No
41/49
Flexlite GX
Operating manual - EN
428W
428WS
MIG/MAG
MIG/MAG
M10x1
M10x1
Manual
Manual
Liquid
Liquid
1
1
5
5
1.9
1.9
1.6
1.6
Kemppi
Kemppi
0.8...1.6
1.2...1.6
-
-
-
-
420 A
300 A
-
-
-
-
-
-
20
20
1.6
1.6
22
22
0.8...1.6
-
0.9...1.6
-
0.8...1.6
1.2...1.6
0.9...1.6
-
0.8...1.6
1.2...1.6
-
-
20°C...+40°C
20°C...+40°C
-
-
40°C...+60°C
40°C...+60°C
Yes
Yes
No
No
No
No
1921390 / 2002