Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Wire Feeder - Kemppi Flexlite GX Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 250

5.1 Troubleshooting

The problems and the possible causes listed are not definitive, but suggest some typical situations that may turn up
during normal use of the welding system. For further information and assistance, contact your nearest Kemppi service
workshop.
General:
The welding system does not power up
Check that the mains cable is plugged in properly.
Check that the mains switch of the power source is at the ON position.
Check that the mains power distribution is on.
Check the mains fuse and/or the circuit breaker.
Check that the earth return cable is connected.
The welding system stops working
The gun may have overheated. Wait for it to cool down.
Check that none of the cables is loose.
The wire feeder may have overheated. Wait for it to cool down and see that the welding current cable is prop-
erly attached.
The power source may have overheated. Wait for it to cool down and see that the cooling fans work properly
and the air flow is unobstructed.

Wire feeder:

The filler wire on the spool unravels
Check that the spool locking cover is closed.
The wire feeder does not feed the filler wire
Check that the filler wire has not run out.
Check that the filler wire is properly routed through the feed rolls to the wire liner.
Check that the pressure handle is properly closed.
Check that the feed roll pressure is adjusted correctly for the filler wire.
Blow compressed air through the wire liner to check that it is not blocked.
Welding gun:
The wire burns into the contact tip
Make sure the size and type of the current tip and liner are suitable for the filler wire.
Make sure the wire liner is clean.
Make sure the wire liner does not make any steep loops.
Check the motor current level. If the current is too high, there may be problems in the wire liner.
Check the tightness of the feeding rolls. Too tight feeding rolls may affect soft filler wires, such as aluminium
and flux-cored wires.
The gun overheats
Make sure the gun's neck is correctly connected to the handle: push the neck deep enough and check that the
neck tightener is properly tightened.
Make sure that the contact tip adapter is properly hand-tightened and the contact tip properly attached to it.
Make sure that the welding parameters are within the range of the welding gun and the neck. The gun and the
neck have separate limits for the maximum current; the lower one of these is the maximum current that can be
used.
The gun neck overheats
© Kemppi
29/49
Flexlite GX
Operating manual - EN
1921390 / 2002

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis