6.1 Technical data: Flexlite GX 200A/250A (gas-cooled)

Flexlite GX
Feature
Welding process
Contact tip
Method of guidance
Type of cooling
Coolant flow rate (l/min)
Coolant max. pressure (bar)
Min. cooling power at 1.6l/min * (kW) IEC 60974-7
Min. flow rate (l/min)
Type of connection
Wire diameters (mm)
Load capacity:
Filler wire diameters (mm):
Operating temperature range
Storage temperature range
Pistol grip handle
Rotating neck
Changeable neck
Neck dimensions:
© Kemppi
35% / Ar + 18% CO₂
60% / Ar + 18% CO₂
100% / Ar + 18% CO₂
35% / CO₂
60% / CO₂
100% / CO₂
Gas flow (l/min) in load capacity test
Filler wire diameter in load capacity test
Stick out length in load capacity test
Fe
Fe-MC/FC
Ss
Ss-MC/FC
Al
Length x (mm) ( see figure below )
Height y (mm) ( see figure below )
203G / 205G
Value
MIG/MAG
M10x1
Manual
Air
-
-
-
-
Euro
0.8...1.2
200 A
-
-
-
-
-
13
1.0
15
0.8...1.2
0.9...1.2
0.8...1.2
0.9...1.2
0.8...1.2
-20°C...+40°C
-40°C...+60°C
Yes
Yes
No
117
80
33/49
Flexlite GX
Operating manual - EN
208GMN
253G / 255G
MIG/MAG
MIG/MAG
M10x1
M6
Manual
Manual
Air
Air
-
-
-
-
-
-
-
-
Kemppi
Euro
0.8...1.2
0.6...1.2
-
250 A
200 A
-
-
-
-
-
-
-
-
-
13
13
1.0
1.0
15
15
0.8...1.2
0.6...1.2
0.9...1.2
0.9...1.2
0.8...1.2
0.8...1.2
0.9...1.2
0.9...1.2
0.8...1.2
0.8...1.2
-20°C...+40°C
-20°C...+40°C
-40°C...+60°C
-40°C...+60°C
Yes
Yes
Yes
Yes
Yes
No
101
114
86
65
1921390 / 2002