Herunterladen Inhalt Inhalt Diese Seite drucken

Nibe SMS 40 Installateurhandbuch Seite 18

Vorschau ausblenden Andere Handbücher für SMS 40:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

SMS COMMAND FOR SETTINGS CHANGES
The following command can be used when you want to make changes in your climate unit via NIBE SMS 40:
Caution
The change command that is sent to NIBE SMS 40 must always be written with a space between the
command and the desired value.
If you want to activate "Temporary lux, hot water" for 12 hours for example, you send the SMS message
"!tlhw 12"
The command is answered with a status message.
Command
Parameter
!op
0/1
!tlhw
0/3/6/12
!reg1
-10–10
!reg2
-10–10
!reg3
-10–10
!reg4
-10–10
!roomt1
5–30
!roomt2
5–30
!roomt3
5–30
!roomt4
5–30
!vac
1/0
!alarm
!vent
0/1/2/3/4
1) Accessories are required
2) Applies to F370, F470, F730 and F750
3) Applies to F1145/F1155 and F1245/F1255
4) Applies to F1345/F1355
5) Before activating the holiday setting, you must select, in the climate unit, what is to occur when holiday mode is activated. For further in-
formation, see the installation manual for your climate unit.
18
Answer
Description
?status
Change operating mode
Auto/add. heat only
?status
Temporary lux, hot water. 0/3/6/12 hours.
?status
Temperature (offsetting the heat curve in systems without room
sensors)
?status
Temperature (offsetting heat curve in systems without room
sensor), climate systems 2
?status
Temperature (offsetting heat curve in systems without room
sensor), climate systems 3
?status
Temperature (offsetting heat curve in systems without room
sensor), climate systems 4
?status
Temperature (setting the room temperature in systems with
room sensors)
?status
Temperature (setting the room temperature in systems with
room sensors), climate system 2
?status
Temperature (setting the room temperature in systems with
room sensors), climate system 3
?status
Temperature (setting the room temperature in systems with
room sensors), climate system 4
?status
activating/deactivating holiday settings
Resets alarm
Changed fan speed. 0= normal fan speed
1)
1)
1)
1)
1)
1)
5)
2), 3+1), 4+1)
NIBE SMS 40 | GB

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis