Adjusting the depth
The ventilation grille 4 (see Fig. 19) is attached
to the air-conduction plates 19 with snap-on
fixings. There are 8 adjacent holes in these air-
conduction plates for adjusting the depth of the
ventilation grille. Remove the ventilation grille
and loosen the nuts on the side of the air-
conduction plates.
First attach the air-conduction plates in the
middle hole and tighten the nuts. Then attach the
ventilation grille and check that it is flush with
the cupboard wall.
If this is not the case, the air-conduction plates
can be moved forwards or backwards until the
depth has been correctly adjusted.
Then secure the air baffle plates with the nuts
you undid beforehand and fit the plinth cover.
Adjusting the height
For height adjustment between 31 and 60 mm,
auxiliary part 20 (Fig. 20) ZB 020-090 can be
ordered if a good appearance is required.
For height adjustment between 61 and 70 mm,
auxiliary part 20 can be used twice.
Connecting to the power supply
Operating voltage 220/240 V
50 Hz
The IK 300 is fitted with a 2.15 m cable and plug
and may be connected to an earthed socket only.
The mains cable must be long enough to allow
the appliance to be removed.
The connection range of the mains cable is
illustrated in Fig. 21 (hatched area).
The connection cable must be fitted in the
groove in the rear plate.
As the appliance occupies the entire housing,
connection to the mains cannot and must not be
behind the IK 300.
First connect the water, then connect the IK 300
to the power supply.
39