42ADF025, 42ADF035
Piping and Drain Hose Forming
Piping and Drain Hose Forming
• Forming the drain hose and refrigerant piping.
• Make a 65mm diameter hole in the wall.
• For corner installation, make an easier hole at either point
left-side or right side.
• Drill a hole at a slope so that the outside end is lower
5-1 Omm than the inside end to ensure good drainage.
[Installation of at walls]
Intdoor
Side or Bottom Piping
• Remove the knock-out in the unit and pass the pipes through
the wall.
• The pipe should slope downward and away from the unit to
ensure good drainage.
6
[Installation of coroner walls]
Under Slant
Outdoor
[Installation of at walls]
Finishing of Pipe
• Tie the pipe, the drain hose, and the electrical connection
cord together.
• Tape the pipe, the drain hose, and the electrical connection
cord together for nishing, and x e the pipe cover with screws.
Indoor pipe
Connecting cord
Drain hose