RML10.4, RML10.4S, RML10.4T
Item in
fig. j,
Description
page 10
12
Lightning
13
Display
14
Fan 2 (if options module is available)
15
Fan 1 (if options module is available)
16
Options module
17
DC supply oven (if options module is available)
18
DCsupply options module
19
CI-Bus connection
20
DC supply cable
21
12 V terminal housing (front view)
22
DC supply cable electronics
23
DC supply cable heating element
24
internal DC supply, max. 1 A (options module, oven, fan)
DC power
!
WARNING! Fire hazard!
• The supply line to the heating element must be protected with a
20 A fuse.
• The supply line to the electronics must be protected with a 2 A fuse.
A
NOTICE!
The respective positive and negative supply lines of the DC connections
for electronics (fig. j 22, page 10) and heating element (fig. j 23,
page 10) may not be joined with one another and carried on a single
wire. This can cause electrical interference or damage to electrical com-
ponents.
Please note the following cable sizes:
• < 6 m (in the interior): at least 6 mm
• > 6 m (in the interior): at least 10 mm
EN
AMP/TE Tyco: 180906
CS Colombo: 63N025
2
2
Connecting the refrigerator
23