Herunterladen Inhalt Inhalt Diese Seite drucken

Avocent SwitchView Bedienungsanleitung Seite 12

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
SwitchView
User Manual
Appendix
10
The following is a summary of all operational commands.
Key Sequence
<CTRL><CTRL>Addr<Enter>
<CTRL><CTRL>Dnn<Enter>
<CTRL><CTRL>SG<Enter>
<CTRL><CTRL>SH<Enter>
<CTRL><CTRL>M+<Enter>
<CTRL><CTRL>M-<Enter>
<CTRL><CTRL>MR<Enter>
<CTRL><CTRL>MW<Enter>
<CTRL><CTRL>Kn<Enter>
<CTRL><CTRL>AV<Enter>
<CTRL><CTRL>H1<Enter>
<CTRL><CTRL>H2<Enter>
<CTRL><CTRL>H3<Enter>
<CTRL><CTRL>H4<Enter>
<CTRL><CTRL>ZM<Enter>
Action
Selects an active channel via keyboard.
Configures the dwell time. Substitute nn with
a value from 2 to 60 seconds.
Enables the scan Go command.
Enables the scan Halt command.
Mouse will suspend scanning.
Mouse will not suspend scanning. (default)
If you hot-plug the SwitchView to a PC con-
nection you may experience a loss of mouse
signal. Use this command to restore the signal
if you're using a PC with a standard PS/2
mouse driver. (See page 8)
Use this command to restore the mouse signal
if you're using a PC with a Microsoft Intel-
liMouse driver. (See page 8)
Sets keyboard scan set; n is a number 1 - 3.
Displays the current firmware version of the
SwitchView processors. You must be at a DOS
prompt or in a text editor/word processor to
view this information.
Default Command Mode Activation
Changes the Command mode activation
sequence to <ALT> <ALT>
Changes the Command mode activation
sequence to <Shift> <Shift>
Changes the Command mode activation
sequence to <NUMLOCK> <->
Used to resynchronize the mouse after a hot-
plug. Repeat, if necessary, until synchroniza-
tion is re-established.
NOTE: Using this command while the mouse
is operating correctly will cause the mouse
to lose sync.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis