Herunterladen Inhalt Inhalt Diese Seite drucken

Applications; Identification; Functions; Operating Conditions - Grundfos Unilift CC 5 Montage- Und Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Unilift CC 5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33

3. Applications

Grundfos Unilift CC 5, CC 7 and CC 9 pumps are
single-stage submersible pumps designed for
pumping rainwater and grey wastewater from
sources such as:
washing machines, baths, sinks, etc. from low-
lying parts of buildings up to sewer level
cellars or buildings prone to flooding
draining wells
wells for surface water with inlets from roof
gutters, pits, tunnels, etc.
swimming pools, ponds or fountains.
The pump is suitable for both stationary and portable
use.
Warning
The pump must not be used in or at
swimming pools, garden ponds, etc.
if there are persons in the water.
The pump is not suitable for these liquids:
liquids containing long fibres
inflammable liquids (oil, petrol, etc.)
aggressive liquids.

4. Identification

2
3
1
5
Type UNILIFT CC7-A1
14
Model 96280968
U1x220-240V~
50Hz
12
P
380W
Q 10m
3
/h
1
Ins.CI.F
11
0197
Made in Italy
96584492
8 9 10
Fig. 2
Example of nameplate for Unilift CC 9
Pos. Description
1
Pump type
2
Frequency
3
Max. head
Max. liquid
temperature
4
during continuous
operation
5
Product number
6
Production code
7
Full-load current
6
6
DIN EN 12050-2
4
P61410
SN0000001-B
7
T max 40°C
H
7m
I
1,8A
max
1/1
IP68
7m
13
DK - 8850 Bjerringbro, Denmark
Pos. Description
8
Max. flow rate
Motor insulation
9
class
10
Enclosure class
11
Approvals
Motor input
12
power
Max. installation
13
depth
14
Supply voltage

5. Functions

Pump with float switch
Automatic start/stop.
Pumping to low water level without suction
strainer, with the pump in forced operation.
Pump without float switch
Manual external start/stop.
Pumping to low water level without suction
strainer. See section
level.
Unilift CC pumps incorporate an air vent valve.
See section
8.1
Self-venting.

6. Operating conditions

Liquid temperature

0-40 °C.
However, at intervals of at least 30 minutes, the
pump is allowed to run at maximum 70 °C for periods
not exceeding two minutes.
Storage temperature
-10 - +50 °C.
Installation depth
Maximum 10 metres below water surface.
Always have at least 3 m free cable
above liquid level. This limits
installation depth to 7 m for pumps
Caution
with 10 m cable and to 2 m for pumps
with 5 m cable.
8.4 Pumping to low water

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Unilift cc 7Unilift cc 9

Inhaltsverzeichnis