6.2 Applications

The lifting station is designed for pumping grey and
black wastewater from family houses and
commercial buildings where the liquid cannot be led
directly to the sewer due to lack of a natural
downward slope.

6.3 Pumped liquids

Unilift CC, Unilift KP, Unilift APB
Grey wastewater, that is domestic wastewater
without toilet discharge.
Unilift AP50B may be used for black wastewater, that
is domestic wastewater with toilet discharge, in
countries allowing outlet pipes of DN 50 for black
wastewater without using a grinder pump.
SEG
Grey and black wastewater, that is domestic
wastewater with toilet discharge.
The SEG pump has a grinder system.
Surface water must not be discharged into a lifting
station inside the building.

6.4 Automatic operation

The lifting station is designed to operate
automatically according to the liquid level in the tank.
You can set the lifting station to automatic operation
in two ways. Equip the lifting station either with float
switches, fitted directly on the pumps, or with a level
sensor tube and a controller.

6.5 Identification

6.5.1 Type key
Unolift: one pump
Model
Duolift: two pumps
Tank volume
270
[litres]
540
Outlet
DN 40
CC
KP
Pump
APB, APB
SEG
UNOLIFT 270. 40. CC
6.5.2 Nameplate
1
DK - 8850 Bjerringbro, Denmark
2
Typ
Prod.-Nr.
3
P. c.
4
f
Hz
5
Phases
6
U
V
7
A
I
1/1
8
P
kW
1
19
0197
98127055
20
9
Fig. 24
Nameplate, lifting station
Pos.
Description
1
Type designation
2
Product number
3
Production code (year and week)
4-8
-
9
CE mark
10
-
11
Serial number
12-14
-
15
Maximum liquid temperature [°C]
16
Maximum ambient temperature [°C]
17
Weight [kg]
18
-
Reference number for the declaration of
19
performance
20
Notified body

6.6 Diaphragm pump

We recommend that you connect a diaphragm pump
to the tank. It is a positive displacement pump which
can be operated manually. It can be used to drain the
tank before service or during power cuts. The tank
has a DN 40 outlet for the pump.

6.7 Level sensor tube

The level sensor is an accessory, which works
together with a controller LC 220 or LC 221.
The level sensor tube is connected to a
piezoresistive level sensor in the controller via the
level sensor hose.
The rising liquid level compresses the air inside the
level sensor tube and hose, and the piezoresistive
sensor transforms the changing pressure into an
analog signal. The controller uses the analog signal
to start and stop the pump and to indicate high-level
alarm.
10
11
Serial no.
12
3
m /h
Q
max
13
m
H
min
14
m
H
max
15
T
Med
C
max
16
Amb
T
C
max
17
G
kg
Made in Germany
18
19

Werbung

loading

Diese Anleitung auch für:

Duolift serie