RMD10
Fault
The refrigerator is not
adequately cooling.
6.1
Fault messages and signal tones
All faults are indicated with a warning symbol, a fault ID and a beep. The beeping
lasts for 2 minutes and is repeated every 30 minutes until the error has been rectified.
If multiple faults occur, the display shows the last fault. The underlying faults are
displayed after the last fault has been confirmed.
RMD10.5T, RMD10.5XT: Faults are indicated by a fault code with a warning
symbol (
) in the middle of the TFT display.
RMD10.5, RMD10.5X: In the event of a fault, the LED warning symbol (
display lights up continuously and the LEDs flash according to the fault.
EN
Possible cause
The ventilation around the
cooling unit is not sufficient.
The evaporator is iced up.
The temperature is set too high.
The ambient temperature is too
high.
Too much food was placed in the
refrigerator at once.
Too much warm food at once
was placed in the refrigerator.
The refrigerator has not been
operating for very long.
Troubleshooting
Suggested remedy
Check that the ventilation grill is not
obstructed.
Check whether the refrigerator door
closes properly. Make sure that the
refrigerator seal fits correctly and is not
damaged. Defrost the refrigerator.
Set a lower temperature.
Remove the ventilation grill for a while
so that warm air can escape quicker.
Remove an item of food.
Remove the warm food and leave it to
cool down before putting it in again.
Check the temperature again after four
or five hours.
in the
)
27