Declaration of compliance
The manufacturer declares that the appliances of their production are compliant with the above
mentioned EEC directives and requires that installation be done observing the norms in force,
regarding particularly the system for letting out fumes and air exchange.
Gas fry-top
Sturdy structure in steel placed on four feet which make it possible to regulate the height in the
version with cabinet. The outside finishing is in stainless steel with Chromium-Nickel 18-10.
It is provided with a thermostatic safety gas valve which enables the regulation of the temperature
in a range from 110° C inclusive to 350° inclusive; safety is ensured by means of a thermocouple
which is kept active by the flame of the pilot burner. The 900 wide versions are provided with two
separate cooking areas, with independent temperature regulating controls.
The hotplate is in thick steel, covered with a protective layer. The chamber is heated by means of a
Chromium-plated steel tubular burner, suitable for proper functioning at the high temperatures to
which it is exposed. For some versions is a plate of compound foreseen.
Electric fry-top
Sturdy structure in steel placed on four feet which make it possible to regulate the height in the
version with cabinet. The outside finishing is in stainless steel with Chromium-Nickel 18-10.
It is provided with a thermostat which makes it possible to regulate the temperature in a range from
150° C inclusive to 350° C inclusive, and with a selector for selecting the type of cooking-only ceil,
only floor or both. The 900 wide versions are provided with two separate cooking areas, with
independent temperature regulating controls.
The hotplate is in thick steel, covered with a protective layer. The heating is done by means of
protected elements. For some versions is a plate of compound foreseen.
Neutral cabinet
Sono disponibili delle applicazioni a vano igienico classe H3 con reggigriglie stampate a
dimensioni GASTRONORM.
Place (fig.5 – pag.4)
It is advisable to install the appliance in a well ventilated room or under an extractor hood. The
appliance may be installed as a single unit or together with others. In both cases, if it is installed
near a wall of inflammable material, a minimum distance of 100mm from the side and back walls
must be observed. In the event that it is not possible to observe this distance, protective measures
must be taken (e.g. use of sheets of refractory material) which ensure that the temperature of the
walls is within the established safety limits.
Non installare l'apparecchiatura con il camino lato operatore, ma sempre accoppiato ad un altro
apparecchio o al muro
DESCRIPTION OF APPLIANCES
PROVISIONS FOR INSTALLATION