5.2.2 Bending procedure for JRG Sanipex MT
Marking of the radian measurement
corresponding to the dimension.
(Refer to technical document., page 42).
Insert the pipe into the bending
template (pay attention to the centre
of the bend).
Attention: Before bending, align the
rotating pin prism in the direction of the
bending template.
Danger
Piston running out!
Human limbs could be injured! The bending tool must only be operated
with the control cable connected and using the start button (30)!
Remark
Slewing range pipe shank
When bending, take into consideration the swivelling range of the free
pipe legs!
®
Installation instructions
pipes d16 - d40
®
Fix the bending angle and adjust the
slide to the appropriate dimension and
fix with the adjusting screw.
Push the start button (30) on the bending
device and hold it pushed. The bending tool
automatically terminates the bending process
when the bending angle adjusted has been
reached. When the start button (30) is
released, the bending process is immediately
aborted. The process can be continued and
terminated by renewed pushing and holding
of the start button.