5.1.1 Installation procedure JRG Sanipex MT

Cut JRG Sanipex MT
or with JRG pipe cutter to the desired
length.
Insert the JRG Sanipex MT
expansion tool right up to the stop, close the
clamping lever. Start the expansion process by
briefly pushing the start button (4) on the
hydraulic device.
Remark
Expanding process break off
A repeated pushing of the start button aborts the expansion process.
Following an abortion, the hydraulic device has to be switched off
and then on again with the mains switch (21).
Warning
Incorrectly formed pipe flares
Incorrectly formed pipe flares must not be flared again!
74
®
Installation procedures
®
Connection technology
®
®
pipe with customary
pipe end into the
®
Installation instructions
®

d16 - d40

Slide the union nut onto the
JRG Sanipex MT
®
pipe.
Open the clamping lever and remove
the flared JRG Sanipex MT
the expansion tool.
pipe from
®