INSTALLATIoN
Power supply
MCB/fuse
Assignment
rating
B 16 A
Electric emergency/
booster heater
(DHC)
B 16 A
Control cable
Electrical data is provided in chapter "Specification / Data table".
Material losses
!
Provide separate fuses/MCBs for the two power circuits,
i.e. for the compressor and the electric emergency/boost-
er heater circuits.

12.1 Electric emergency/booster heater

General
Appliance
effect of the electric emergency/booster heater
function
Mono energet-
If the heat pump undershoots the dual mode point, the elec-
ic operation
tric emergency/booster heater safeguards both the heating
operation and the delivery of high DHW temperatures.
Emergency
Should the heat pump suffer a fault that prevents its contin-
mode
ued operation, the heating output will be covered by the elec-
tric emergency/booster heater.
Power connection
X3 electric emergency/booster heater (dHC)
L1, L2, L3, N, PE
Connected load
2.9 kW
5.9 kW
8.8 kW

12.2 Control voltage

www.stiebel-eltron.com
Cable cross-section
2.5 mm² for routing through a wall.
1.5 mm² with only two live cores and
routing on a wall or in an electrical con-
duit on a wall.
1.5 mm²
Terminal assignment
L1
PE
L1
L2
PE
L1
L2
L3
PE
X4
Control voltage (control outputs)
DHW
DHW charging pump and N (X25), PE
Zirk.
DHW circulation pump N (X25), PE
2.WEWW
2nd DHW heat generator and N (X25), PE
M(Z)
Mixer close
M(A)
Mixer open
MKP
Mixer circuit pump and N (X25), PE
HKP
Heating circuit pump and N (X25), PE
KUE/Solar
Solar circuit pump / cooling output
2. WE
Heat source 2 and N (X25), PE
EVU
Enable signal
L (mains)
X24 Pe
X25 N
Material losses
!
f Only connect energy efficient circulation pumps ap-
f
proved by us to the pump connections.
If you are using energy efficient circulation pumps that
have not been approved by us, use a relay with a break-
ing capacity of at least 10 A/250 V AC or our WPM-RBS
relay set.

12.3 Low voltage, BUS cable and service

X2 Safety extra low voltage
Fernb. 3
Remote control
Fernb. 1
Remote control
T(MK)
Mixer circuit temperature sensor and earth (X26)
T(AUSSEN)
Outside temperature sensor and earth (X26)
T(WW)
DHW cylinder sensor
T(KOLL)
Collector sensor
T(KUE)/T(WW) DHW temperature sensor, bottom, in the case of solar
connection
Flow sensor, in the case of cooling
T(2. WE)
Temperature sensor, heat generator 2
T(Puffer)
Buffer cylinder sensor
X1
Service (CAN BuS)
H
High
L
Low
Ground
+
(only in conjunction with FEK)
X26 gNd
HSBB 3 |