INSTALLATIoN

Safety

INSTALLATIoN
8.
Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
8.1

General safety instructions

We guarantee the trouble-free function and operational reliabil-
ity only if original accessories and spare parts intended for the
appliance are used.
8.2

Instructions, standards and regulations

Note
Observe all applicable national and regional regulations
and instructions.
9.

Appliance description

9.1

Standard delivery

The following are delivered with the appliance:
- 1 contact sensor
- 1 outside temperature sensor AFS 2
- 4 appliance feet
- 4 sliding blocks for the appliance feet
9.2

Accessories

- Remote control for heating operation
- High limit safety cut-out STB-FB
- Pressure hoses
- Water softener HZEA

10. Preparations

10.1 General information

To reduce line losses, keep the distance short between the appli-
ance and the heat pump.

10.2 Installation site

Material losses
!
Never install the appliance in wet rooms.
Installation site requirements:
- free from the risk of frost
- The room must not be subject to a risk of explosions arising
from dust, gases or vapours.
- Load-bearing floor (for the weight of the appliance, see
chapter "Specification / Data table")
28
| HSBB 3
- If you are installing the appliance in a boiler room together
with other heating equipment, ensure that the operation of
other heating equipment will not be impaired.

10.3 Transport

Material losses
!
The appliance is unsuitable for lifting by hoist.
Material losses
!
Store and transport the appliance at temperatures of
+5 °C to +50 °C.
f To protect the appliance from damage, transport it in its
f
packaging.
f Use the angle brackets at the back of the appliance as a
f
transport aid.
Where space for transport is restricted, you may also move the
appliance tipped backwards at an angle.
Material losses
!
Fittings may come loose during transport.
f After transport, check all fittings on the cylinder and
f
on the hydraulic assembly for tightness.
f Retighten the fittings if required.
f

10.4 Minimum clearances

≥500
f Maintain the minimum clearances in order to ensure trou-
f
ble-free operation of the appliance and to allow enough
space for maintenance work.
≥100