Syphon connection
The waste connection must be at a height of between 50cm (minimum) and 100cm (maximum)
from the bottom of the dish. The water drain hose should be fixed by a hose clip.
When starting the dishwasher you should check:
• Whether the dishwasher is level and fixed and the inlet valve is opened.
• Whether there is leakage at the connections of the conducts.
• Whether the wires are tightly connected and the power is switched on.
• Whether the inlet and drain hoses are knotted.
• All packing materials and printings should be taken out from the dishwasher.
Loading the Salt into the Softener
The water softener is designed to remove minerals and salts from the water, which would have a detrimental
or adverse effect on the operation of the appliance. The higher the content of these minerals and salts, the
harder the water is. The softener should be adjusted according to the hardness of the water in your area. Your
local Water Authority can advise you on the hardness of the water in your area.
1. Find out about the hardness value of your tap water. Your water utility company will help you.
2. Set value can be found in the water hardness table.
3. Close the door.
4. Switch on „Power" switch.
5. Hold down „Delay" button and then press „Program" button for 5 seconds.The buzzer rings one time and H.
flashes on the digital display (factory setting is H4).
6. To change the setting press „Delay„ button. Each time the button is pressed, the set value increasesby one
level. When the value of H7 has been reached, the display jumps back to H0(off).
7. Press „Program„ button. The chosen setting has now been stored.
Hardness (°Clark)
0-8
9-10
11-12
13-15
16-20
21-26
27-38
39-62

Before first Use

Range
soft
soft
soft
medium
medium
hard
hard
hard
Value
H0
H1
H2
H3
H4
H5
H6
H7