IMPORTANT REMARKS
Attention: for people safety it is important to follow carefully
the instructions. Keep the instructions.
Important safety instructions for the installation.
Attention: a wrong installation can cause serious accidents.
Follow carefully the installation instructions .
This device can be installed only from qualified persons.
As regards insulation, the features of push buttons must be
suitable for electrical installations (230VAC - 50Hz / 120VAC -
60Hz).
In order to protect the device, the installer must provide for
a magnetotermical differential switch (separation among the
contacts: at least 3 mm), ensuring the omnipolar sectioning
from the power supply.
In order to grant the tightness of the case it is necessary to
remove the protective sleeve of the cables used for wiring (see
the picture).
EU DECLARATION OF CONFORMITY
V2 S.p.A. hereby declare that CU1 products conform to the
essential requirements established in the following directives:
• 2014/30/UE (EMC Directive)
• 2014/35/UE (Low Voltage Directive)
• 2014/53/UE (Radio Directive)
• ROHS2 2011/65/CE
Racconigi, lì 01/06/2015
V2 S.p.A. legal representative.
Giuseppe Pezzetto
DESCRIPTION
This automatic opening system consists of a control unit with the
following features:
It is provided with a 434.15 MHz super-heterodyne radio
receiver.
Up to 48 different channel can be stored on each central unit.
It is driven by means of transmitters PROTEO, DUO, ARTEMIS,
ADLER and DEV-T1.
It is possible to drive the awning / rolling shutter also by mean
of an external push-button (type: Normally Open, each series
or model).
The programming phase can be effected via radio or by means
of an external switch.
It is necessary to use a sesor model WIND, MISTRAL, METEO,
HURRICANE.
TECHNICAL SPECIFICATIONS
Power supply: 230VAC - 50/60Hz / 120VAC - 60Hz
Relay contact capacity: 10A
Sensitivity of receiver: -105 dBm @ S/N = 17 dB (m = 100%)
Protection: IP55
FUNCTIONING WITH EXTERNAL WIRED
SWITCH
Pressing the external wired switch, the control unit has the
following functioning logic:
a
a
OPENS
STOPS
CLOSES
FUNCTIONING WITH TRANSMITTERS
At each push button pressure, the functioning logic is the
following.
a
UP:
CLOSES
a
STOP:
STOPS
STOPS
a
DOWN:
OPENS
OPENS
SENSOR ACTIVATION
To activate the sensors function, at least one transmitter must be
stored.
m
IMPORTANT:
Anemometer causes inhibition of functioning of both radio
transmitter and external push button for ca. 8 minutes.
The anemometrical sensor should be installed close to the
awnings, in order to avoid damages in case of very strong
wind.
WORKING TIME OF MOTOR
The control unit stops the motor movement after 2 minutes: in
case of limit switches malfunction this "time out" avoids the
motor overheating.
- 16 -
a
a
STOPS
OPENS ...
a
CLOSES
CLOSES
a
STOPS
a
OPENS