Accuracy Table
PEAK MAX/PEAK MIN
Accuracy guarantee range
Range
6.000 V
0 V to ±12.00 V (0.01 V)
60.00 V
±3.0 V to ±120.0 V (0.1 V)
600.0 V
±30 V to ±1000 V *
1000 V
±50 V to ±1000 V *
*1: Frequency range of 15 Hz ≤ f < 20 Hz is designed value.
*2: Within the frequency range of f < 45 Hz, the accuracy guarantee assumes a superposed DC voltage of
less than 500 V.
*3: Values of up to ±1200 V are displayed, but accuracy is not defined for display values in excess of 1000 V
(which are provided as reference values).
*4: Values of up to ±1700 V are displayed, but accuracy is not defined for display values in excess of 1000 V
(which are provided as reference values).
48
(Resolution)
3
(1 V)
4
(1 V)
Accuracy guarantee
1
frequency range *
15 Hz ≤ f < 45 Hz
45 Hz ≤ f ≤ 66 Hz
66 Hz < f ≤ 1 kHz
15 Hz ≤ f < 45 Hz
45 Hz ≤ f ≤ 66 Hz
66 Hz < f ≤ 1 kHz
15 Hz ≤ f < 45 Hz
45 Hz ≤ f ≤ 66 Hz
66 Hz < f ≤ 1 kHz
15 Hz ≤ f < 45 Hz
45 Hz ≤ f ≤ 66 Hz
66 Hz < f ≤ 1 kHz
Measurement accuracy
2
*
±1.8% rdg.±0.07 V
±1.5% rdg.±0.07 V
±1.8% rdg.±0.07 V
±1.8% rdg.±0.7 V
±1.5% rdg.±0.7 V
±1.8% rdg.±0.7 V
±1.8% rdg.±7 V
±1.5% rdg.±7 V
±1.8% rdg.±7 V
±1.8% rdg.±7 V
±1.5% rdg.±7 V
±1.8% rdg.±7 V