Accuracy
We define measurement tolerances in terms of f.s. (full scale), rdg. (reading) and dgt. (digit) values with the
following meanings:
f.s.
(maximum display value/range)
The maximum displayable value. This is usually the name of the currently selected range.
rdg.
(displayed value)
The value currently being measured and displayed on the measuring instrument.
dgt.
(resolution)
The smallest displayable unit on a digital measuring instrument, i.e., the input value that causes
the digital display to show a "1" as the least-significant digit.