Herunterladen Inhalt Inhalt Diese Seite drucken

wiking Miro 1 Installations- Und Bedienungsanleitung Seite 24

Vorschau ausblenden Andere Handbücher für Miro 1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The stove is mainly made of sheet iron, with some items made of cast iron .
Nominal output:
Smoke temperature:
Exhaust gas mass flow:
Efficiency
Distance to Inflammable Materials
In the table below you can see the minimum distance to the closest combustible and non-
combustible walls .
Distance from the Wood-burning Stove to...
brick wall behind the unit .
brick wall to the side of the unit .
combustible wall behind the unit .
combustible wall to the side of the unit .
For wall-mounting, the stove must be placed at least 7 cm above any inflammable flooring. This
also applies to any floorboard placed on the floor.
Please be aware that not all glass parts are heat-resistant . For this reason, a glass wall should
sometimes be treated as a flammable wall, in which case we ask that you please contact your local
chimney sweep or glass producer to hear at what distance the stove should be kept from glass .
Height Requirements
The WIKING Miro has a smoke outlet at the top and at the back . It can be installed with an
approved smoke pipe and a steel chimney, or connected to a brick chimney with a fullform
smoke pipe .
Connection to the Chimney
The chimney must be of a proper height to ensure that the draft is sufficient and that smoke does
not become bothersome . If the chimney is so high that it cannot be cleaned from the top, an
easily accessible cleaning hatch must be installed . We recommend, however, that you always
contact your local chimney sweep before purchasing a chimney .
Make sure that the chimney is tight and that no false draft is caused around neither the cover
plate, in connection with a covered smoke outlet, nor the cleanout door and pipe connections .
Please note that bent and/or horizontal smoke pipes will reduce the effect of the chimney draft .
Requirements for Chimney and Smoke Pipe
Nominal draft: Approximately 12 Pascal/1 .2 mm water gauge .
Minimum clearance: Ø150 mm, which corresponds to your WIKING wood-burning stove's
exhaust pipe .
24
4 .9 kW according to EN norm
285
o
C
4 .0 g/s
80 .2%
WIKING Miro 1/
WIKING Miro 3
Distance, cm
5
15
10
52
WIKING Miro 2/
WIKING Miro 4
Distance, cm
5
15
10
27

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Miro 2Miro 3Miro 4