6.2 Operating mode
In operating mode the display may simultaneously show 4 dif-
ferent situations/values.
1 = Status fan situation, image coupled appliances (see
§ 6.2.1)
2 = Air flow rate (see § 6.2.2)
3 = Message text e.g. text filter situation, activation exter-
nal switch contact etc. (see § 6.2.3)
4 = Fault symbol (see § 8.1 and § 8.2)
6.2.1 Status system fan
This part of the display shows a fan together with a number.
When the supply and extract fans are running, the fan sym-
bol is displayed. When the fans are stopped, the fan symbol
is not visible.
The number behind the fan symbol indicates the fan situa-
tion. Refer to the table below for an explanation of the num-
bers.
Status fan
Description
situation on display
The supply and extrad fans are running at 50 m
This situation depends on setting parameter 1 (see Chapter 13)
The supply and extract fans are running under mode 1 of the multiple switch.
1
Air flow rate depends on setting parameter 2 (see chapter 13).
The supply and extract fans are running under mode 2 of the multiple switch.
2
Air flow rate depends on setting parameter 3 (see chapter 13).
The supply and extract fans are running under mode 3 of the multiple switch.
3
Air flow rate depends on setting parameter 4 (see chapter 13).
This Ubiflux is coupled with the aid of eBus.
The supply and extract fans of the Ubiflux are running under switched mode of the ventilation mode
"master" Ubiflux; in addition, (only for cascade connection) the display shows the "slave" number of the
relevant Ubiflux.
Air flow rate depends on the set parameters "master" Ubiflux.
When using a 3-way switch, the position
1)
6.2.2 Display air flow rate
This shows the set air flow rate of the supply of extract fan.
When when the air flow rates of the supply and extract fans
differ, for instance when using an external switch contact, in
all cases the highest air flow rate is shown.
When the appliance is switched off through software, the
text "OFF" appears here.
20
/h or are inactive.
3
can not be used.
Ubiflux W300(+) / W400(+) / W450(+)