19.7.
Replacing the inlet filter and pre-filter
(Fig. 17)
The inlet filter is located inside the compressor crankcase cover.
Inlet filter replacement:
 Pull out the rubber plug by hand (2).
 Remove the used filter (1).
 Insert a new filter and replace the
rubber plug.
Pre-filter replacement:
 Pull out the pre-filter by hand (3).
Replace the element and re-insert.
19.8.
Filter element replacement
(Fig. 18)
 Remove the hose (1) from the quick connector.
 Use a wrench (2) to release the filter vessel (3) and remove.
 Pull down on the filter element (4) to remove.
 Insert a new filter element.
 Re-install the filter vessel.
 Gently tighten the filter vessel with the wrench.
 Re-install the hose on the quick connector.
Fig. 18
19.9.
Cooler and fan check (Fig.1)
The equipment, in particular the compressor fan, cooler fan (21), and the cooler (14), must be kept
clean to ensure efficient drying. Remove dust from surface of the fan or cooling fins by vacuuming
or blowing down with compressed air.