7

Technical data

7.1
General
Input
Measuring span (continuously adjustable)
Output
Output signal
Operating conditions
Ambient conditions
● Ambient temperature
Note
Transmitter
Storage temperature
● Degree of protection
● Electromagnetic compatibility
Interference emission and
interference immunity
Permitted pressures
Medium conditions
● Process temperature
SITRANS P500 with HART
A5E02344532-03, 04/2013
Devices identified by this symbol may not be disposed of in the municipal waste
disposal services under observance of the Directive 2002/96/EC on waste electronic
and electrical equipment (WEEE).
They can be returned to the supplier within the EC or to a locally approved disposal
service. Observe the specific regulations valid in your country.
Measuring span
1.25 ... 250 mbar
(0.5 ... 100 inH
2
6.25 ... 1250 mbar
(2.51 ... 502 inH
0.032 ... 6.25 bar
(12.54 ... 2509 inH
0.16 ... 32 bar
(2.33 ... 465 psi)
4 ... 20 mA, with modulated HART signal
Observe the temperature class in hazardous areas.
-40 ... +85 °C (-40 ... 185 °F)
Display not legible: -40 ... -20 °C (-40 ...-4 °F)
Display legible: -20 ... +85 °C (-4 ... +185 °F)
-50 ... +90 °C (-58 ... 194 °F)
IP66/IP68 and NEMA 4x (with appropriate cable gland)
As per EN 61326 and NAMUR NE 21
As per 97/23/EC Pressure Equipment Directive
Maximum operating pressure MAWP
(PS)
160 bar (2320 psi)
O)
O)
2
O)
2