Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Cleaning; Maintaining And Cleaning The Tap; Replacing The Cartridge - Miomare Premium Montage-, Bedienungs- Und Sicherheitshinweise

Brause-armatur
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation / Maintenance and Cleaning
Check the operation of the fitting. To do so, swing
the handle
into all permissible positions.
1
Note: If the tap has not been used for a long pe-
riod, flush the pipes thoroughly to avoid stagnation
and build-up of residue.
Open the main water supply.
Life the handle
1
in order to regulate the speed or temperature
of the water.
Hot water:
Swing the handle
to the left.
1
Cold water:
Swing the handle
to the right.
1

Maintenance and Cleaning

Maintaining and cleaning the tap

Please note that sanitary taps require special care
and attention. Therefore, please follow the instructions:
When cleaning, never use petrol, solvents, ag-
gressive cleansers or hard cleaning brushes etc.
These could damage the surface of the product.
Dry your taps with a cloth after every use in
order to avoid the build-up of any limescale.
Clean the product with a damp, soft cloth and
a mild cleaning agent if required.
Non-observance of the above care advice can be
expected to result in damage to the surfaces of the
product. This will inevitably invalidate the guarantee.

Replacing the cartridge

A cartridge
is a wear part that needs replacing
6
according to the hardness and / or degree of con-
tamination of the water. This becomes evident when
the handle
becomes difficult to move. A new
1
cartridges
can be obtained from the listed ser-
6
vice office.
20 GB
and swing it up and down
Note: this step requires an open-end spanner
SW 27 mm or fitting pliers.
Proceed as follows to replace the cartridge
Shut off the main water supply. Allow any re-
maining water in the pipework to drain.
Remove the hot / cold plaque
the handle to the highest position between the
rim and the hot / cold plaque
of the handle
.
1
Note: Use light pressure to carefully push the
hot / cold plaque
2
the surface.
Loosen the locking screw
head wrench
by turning it counter-clockwise.
16
CAUTION! Do not completely unscrew the
locking screw
. Only loosen this as far as is
3
necessary to remove the handle
Remove the handle
Unscrew the cartridge covering ring
use pliers or a spanner. Otherwise the product
could be damaged.
Loosen the cartridge locknut
fitting pliers or an open-ended spanner SW 27 mm
and remove the entire cartridge
ting body
.
7
Place the new cartridge
the tap
in exactly the same way.
7
Note: Be sure that the seal under the cartridge
is correctly in place. Make sure that the
6
guides are in the corresponding holes.
Reassemble all the above parts. Tighten the
cartridge lock nut
5
open-end spanner SW 27 mm while simultane-
ously securing the fitting from twisting. This will
achieve tightness and ensure the handle is not
difficult to move.
CAUTION! Be careful not to reverse the hot /
cold water plaque
The correct position is as follows:
left = red (hot water)
right= blue (cold water).
:
6
by adjusting
2
and the outside
2
outward so as not to scratch
with the socket
3
.
1
.
1
, do not
4
below with the
5
from the fit-
6
into the body of
6
using fitting pliers or an
.
2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis