The cabinet for the DK50-10S/M 10 bar model compressor is equipped with a
cooling fan and a switch. The cabinet must be connected using the provided cord with
connector to the matching connector on the compressor's electrical panel. (Fig. 4)
Ensure the electrical cable does not touch hot compressor components. Risk of
electric shock!
If any electrical cord or air hose is damaged it must be replaced immediately.
Jumper removal
Remove the jumper from the terminal strip in the electrical panel for cabinet-mounted compressors.
The switch on the compressor cabinet will not work properly if the jumper is not removed!
Remove the cover on the electrical panel.
Remove the jumper from the terminal strip.
Reinstall the cover on the electrical panel.
Keep the removed jumper for service purposes (see Chapter 19.11 - Jumper connections).
Compressor with jumper installed
230V
Compressor with jumper removed
230V
05/2019
- 21 -
NP-DK50-10-7_05-2019-MD