Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• During installation of the product by qualified trained
personnel, make sure that the entire fastening surface
is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the
product and has no weak points.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
The product is exclusively designed for drinking water!
4
English
max. 0,6 MPa
0,15 - 0,4 MPa
1,6 MPa
max. 60 °C
< 50 °C
Assembly see page 6 (26618000)
Assembly see page 5 (26687000)
Symbol description
Do not use silicone containing acetic acid!
Dimensions
(see page 8)

Flow diagram

(see page 8)
Spare parts
(see page 12)
Cleaning
(see page 9)