Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Thermal disinfection:
• Safety against backflow
• The product is exclusively designed for drinking
water!
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 6)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions (see page 8)
Flow diagram (see page 8)
Normal spray
Regular
Fault
Mixer stiff
Mixer dripping
Water escaping at the threaded
base
Hot water temperature too low
2
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- O-ring at the connection hose
defective.
- Hot water limiter incorrectly set
Assembly (see page 4)
English
Cleaning (see page 10)
If the waterflow drops, clean the filter located between
hose and handspray.
Maintenance (see page 10)
The check valves must be checked regularly according
to EN 806-5 in accordance with national or regional
regulations (at least once a year).
Spare parts (see page 8)
XX = Colors
00 = Chrome Plated
67 = Matt Black
Operation (see page 7)
Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or after
a prolonged period of non-use.
Remedy
- Exchange cartridge
- Exchange cartridge
- Exchange O-ring
- Set hot water limiter