RMA 339.0
Width
42 cm
Height
107 cm
Weight (without
battery)
14 kg
Hand-arm vibrations:
Specified vibration characteristic in
accordance with EN 12096:
Measured value a
1,60 m/sec
hw
Uncertainty K
0,80 m/sec
hw
Measurement in accordance with
EN 20643
RMA 339.0 C
Length
135 cm
Width
43 cm
Height
110 cm
Weight (without
battery)
16 kg
Hand-arm vibrations:
Specified vibration characteristic in
accordance with EN 12096:
Measured value a
1,60 m/sec
hw
Uncertainty K
0,80 m/sec
hw
Measurement in accordance with
EN 20643

19.1 STIHL AK battery

Battery technology
Lithium-ion
Voltage
36 V
Capacity in Ah
See rating plate
Energy content in
Wh
See rating plate
Weight in kg
See rating plate
Permissible tempera-
ture range
-10°C to +50°C
0478 131 9927 B - EN
This symbol indicates the
number of cells and the energy
content according to the cell
manufacturer's specifications.
The available energy content is
lower in practice.

19.2 STIHL charger AL 101

2
Rated voltage
2
Nominal output
Charge current
Permissible tempera-
ture range
Protection class II. The charger
housing features double
insulation to the connected
mains.
Please refer to www.stihl.com/charging-
times for charging times.
2

19.3 REACH

2
REACH is an EC Directive for the
registration, evaluation, authorisation and
restriction of chemicals.
Information on compliance with the
REACH Directive (EC) No. 1907/2006 is
available from www.stihl.com/reach.

20. Troubleshooting

If necessary, contact a specialist
dealer; STIHL recommends STIHL
specialist dealers.
Fault:
Motor not starting
Possible cause:
– Battery charge state too low – 1 LED
flashes green on battery
– Battery too cold/too warm – 1 LED
illuminates red on battery
– Battery fault – 4 LEDs flash red on
battery
220-240 V,
– Lawn mower is too warm – 3 LEDs
50-60 Hz
illuminate red on battery
75 W
– Lawn mower fault – 3 LEDs flash red on
1.5 A
battery
– ON button not pressed
– Safety plug is not inserted
+5°C to +40°C
– Electrical connection interrupted
between lawn mower and battery
– Motor is overloaded because grass is
too tall or too wet
– Humidity in machine and/or battery
– Mower housing is blocked
– Fuse in safety plug is defective
Remedy:
– Recharge battery (
– Warm up battery or allow it to cool down
– Remove and re-insert battery; consult
specialist dealer if necessary ( )
– Allow lawn mower to cool down
– Clean electric contacts in battery
compartment (
specialist dealer if necessary ( )
– Press ON button (
– Insert safety plug (
– Insert battery correctly (
electric contacts in battery
compartment (
– Do not switch on motor in high grass,
adapt cutting height (
– Remove battery and dry; clean and/or
dry battery compartment (
– Clean mower housing (
– Replace safety plug ( )
8.4)
13.2); consult
12.2)
9.2)
8.3); clean
13.2)
9.6)
8.3)
13.2)
57