Recommended Nozzles; Electrodes Adjustment - Air Regulation - baltur BTL14P Betriebsanleitung

Zweistufige heizölbrenner
Vorschau ausblenden Andere Handbücher für BTL14P:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
NOZZLE
Burner model
BTL 14P
BTL 20P
BTL 26P
NOTE:
The values repoted on this table are
referred at the 12% CO
at the mean
2
sea level and with 0.1 mbar pressure
in the combustion chambre.
PRINCIPLE DIAGRAM DISK-ELECTRODES SETTING
After having installed the nozzle, check the correct position of the electrodes and disk according
to the following levels. It's adviseable to check levels after every intervention on head.
N.B. To prevent damage to the support effect nozzle assembly/disassembly tasks with
the aid of a wrench and counter-wrench.
22
Pump
Burner flow-rate
pressure
TYPE
GPH
bar
12
1,75
22
10
2,50
22
10
2,50
22
10
3,00
22
10
4,00
18
10
4,50
16
10
4,00
22
10
5,00
18
10
6,00
16
NOTE:
The values indicated in the table are purely
indicative; for best burner performance
adjustment needs to be made in accordance
with the demands of the particular boiler type.
TWO STAGE LIGHT OIL BURNERS
ADJUSTMENT DATA
3
Servomotor
adjustment
kg/h
50 Hz
7,00
9,00
45°
9,50
14,00
90°
9,20
13,40
45°
11,20
10°
16,10
90°
14,75
15°
20,40
90°
16,70
20°
21,75
90°
14,75
10°
21,20
90°
20,00
22°
26,80
90°
22,40
30°
27,00
90°
BTL 14P
BTL 20P
BLT 26P
N.B. Ignition can be improved under certain working
conditions by slightly adjusting the position of the
electrodes.
2
Disc position
adjustment
60 Hz
Set-point n°
2
35°
2
5,5
70°
5,5
0
35°
0
2,5
70°
2,5
5
10°
5
70°
15°
7
70°
7
3
70°
3
7
70°
7
20°
7
80°
7

RECOMMENDED NOZZLES

Delavan type B 60° (14P)
MONARCH type R 60° (14P)
Delavan type W 60° (20P- 26P)
N° 0002934112
Rev. 10/02/2004
MOD.
A
B
C
5
0,5-1 5-5,5 3,5-5
4,5
0,5-1 5-5,5 3,5-4
6,5
0,5-1 5-5,5 3,5-4
D