2
1
1
CONTROL FUNCTION
Engine switch
The engine switch controls the ignition system.
1 "7" (ON)
Ignition circuit is switched on.
The engine can be started.
2 "5" (STOP)
Ignition circuit is switched off.
The engine will not run.
7DK-018
Recoil starter
The recoil starter is used to start the engine.
Pull the recoil starter slowly until it is engaged, then
pull it briskly.
1 Recoil starter handle
NOTICE
9 Pull the recoil starter handle straight.
9 Return the recoil starter handle slowly.
9 Do not touch the recoil starter handle while
the generator is operating.
Oil warning light (Red)
When the oil level falls below the lower level, the oil
warning light comes on and then the engine stops
automatically. Unless you refill with oil, the engine will
not start again.
TIP
If the engine stalls or does not start, turn the engine
switch to ON and then pull the recoil starter. If the oil
warning light flickers for a few seconds, the engine oil
is insufficient. Add oil and restart.
700-115