ATTENTION!
After welding, the welding clamp and
the welding rod must be set down on the
insulated holder. The fusion slag can only
be removed once the rod has cooled down.
To re-weld the interrupted weld, the fusion
lag must first be removed from the welding
position.
ATTENTION!
A voltage 10 % below the rated input volt-
age of the welding tool may result in:
A drop in the current of the tool.
The arc stopping or becoming unstable.
z Welding
Choose from welding with the tool directed towards the unwelded or the welded part.
The following illustrates how the direction of movement has on the quality of the weld:
Weld penetration
Weld width
Welding bead
Weld imperfections
Note: Determine which welding method is
more suitable for yourself after welding a test
piece.
Note: Once it has worn down completely,
the electrode must be replaced.
Start up / Welding / Maintenance and Cleaning
ATTENTION!
The arc radiation may cause inflamma-
tion of the eye and skin burns.
Spray and fusion slag may cause eye
injuries and burns.
Wear tinted eye goggles or a face
shield.
The face shield must comply with safety
standard EN175.
Only use welding cables included in
delivery (10 mm2).
Towards the unwelded
part:
less
larger
flatter
greater
z Maintenance and Cleaning
Note: The welding tool requires regular
maintenance and reconditioning to work
properly and to comply with safety require-
ments. Improper and incorrect operation
may result in malfunctions and damage the
tool.
Towards the welded
part:
greater
smaller
higher
less
GB/CY